泛美超声波前置放大器/奥林巴斯前置放大器panametrics 5660/5662/5670/5676/5678系列各款型号概述:
1、5660B泛美超声波前置放大器可与超声探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪音的放大。这款仪器具有以下性能:20 kHz~2 MHz带宽,可选的40 dB和60 dB电压增益。
2、5660C泛美超声波前置放大器可与超声探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪声的放大。这款仪器具有以下性能:500 Hz~2 MHz带宽,可选的40 dB和60 dB电压增益。
3、5662泛美超声波前置放大器可与超声波探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪声的放大。这款仪器具有以下性能:50 kHz~2 MHz带宽,可选的34 dB和54 dB电压增益。
4、5670泛美超声前置放大器可与超声探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪声的放大。这款仪器具有以下性能:50 kHz~10 MHz带宽,40 dB电压增益。
5、5676泛美超声前置放大器可与超声探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪声的放大。这款仪器具有以下性能:50 kHz~20 MHz带宽,40 dB电压增益。
6、5678泛美超声前置放大器可与超声探伤仪、测厚仪、声学发射仪器一起使用,可对超声信号进行超低噪声的放大。这款仪器具有以下性能:200 kHz~40 MHz带宽,40 dB电压增益。
7、5682泛美超声波前置放大器提供超声信号的低噪声30 dB放大效果,范围为500
KHz到25 MHz。前置放大器装于结实防溅的外壳中,其机身小巧、重量极轻,是一款适用于远程应用的理想设备。
泛美超声波前置放大器/奥林巴斯前置放大器panametrics 5660/5662/5670/5676/5678系列英文概述:
Olympus wideband series of Panametrics AC coupled, broadband preamplifiers provides very low noise amplification of ultrasonic signals ranging from 500 Hz to greater than 40 MHz. Specifically designed for use with ultrasonic flaw detection, thickness gaging, and acoustic emission instrumentation, our preamplifiers are a cost-effective solution in general applications requiring high gain/low-noise amplification of low amplitude ultrasonic signals.
Our preamplifiers are ruggedly housed, completely self-contained, simple to operate, battery or AC powered units. They offer performance features such as very low noise (5 µV peak-to-peak noise referred to the input in Model 5660B), input protection for high voltage transients such as transducer excitation pulses, and the ability to drive long coaxial cables (greater than 500 feet or 152 meters with Models 5660B and 5660C). Both fixed gain and switchable gain versions are available, and custom units with special gain or bandwidth are available on special order.
Applications
Certain ultrasonic applications require the addition of a separate preamplifier unit to standard test systems in order to provide the additional gain or broadband signal-to-noise enhancement necessary for optimum signal acquisition. This is often the case in industrial applications involving flaw detection or thickness gaging of thick sections of materials exhibiting high ultrasonic attenuation such as nodular cast iron, brass, bronze, austenitic steel, rubber, Teflon®, or reinforced composites. A preamplifier is also an important component of acoustic emission test systems that require amplification of low signal amplitude events and the ability to drive long cables from remotely located sensors.
Panametrics preamplifiers have also been used in many widely diversified research applications including seismic studies, determination of the size and number versus scattered frequency relationship for acoustic scatterers in water (gas bubbles, zooplankton), crack detection in graphite vacuum arc-melt electrodes, and biological tissue analysis.
泛美超声波前置放大器/奥林巴斯前置放大器panametrics 5660/5662/5670/5676/5678系列技术规格表:
型号
|
5660B
|
5660C
|
5662
|
5670
|
5676
|
5678
|
电压增益
|
40&60dB可切换(阻尼>1kΩ)
|
34&54dB可切换(阻尼=50Ω)
|
40dB固定(阻尼=50Ω)
|
带宽(-3dB)
|
20kHz~2MHz
|
500Hz~2MHz
|
50kHz~5MHz
|
50kHz~10MHz
|
50kHz~20MHz
|
50kHz~40MHz
|
等效输入噪声
|
5μVp-p
|
10μVp-p
|
15μVp-p
|
20μVp-p
|
30μVp-p
|
输入阻抗
|
1MΩ
|
100kΩ
|
输入电容
|
约320pf
|
约80pf
|
输入保护
|
300V峰值(脉冲宽度<2μs,大负载循环1%)
|
输出电压
|
5Vp-p(阻尼>1kΩ),2Vp-p(阻尼=50Ω)
|
2Vp-p(阻尼=50Ω)
|
输出阻抗
|
50Ω-与4.7fd串联
|
大输出电缆长度
|
>152m
|
15m
|
电源要求
|
电池16V±2V,线电压110/115或230VAC
|
耗电电流
|
18mA
|
28mA
|
电池寿命
|
100小时
|
70小时
|
尺寸
|
76x51x127mm
|
重量
|
0.64kg
|
工作温度
|
0~50℃
|
泛美超声波前置放大器/奥林巴斯前置放大器panametrics 5660/5662/5670/5676/5678系列英文技术规格:
All specifications are subject to change without notice
more information of the panametrics preamplifiers please contact us.
other instruments:ferrite determ铁素体测量仪SP10a