泛美超聲波前置放大器/奧林巴斯前置放大器panametrics 5660/5662/5670/5676/5678系列各款型號概述:
1、5660B泛美超聲波前置放大器可與超聲探傷儀、測厚儀、聲學發射儀器一起使用,可對超聲信號進行超低噪音的放大。這款儀器具有以下性能:20 kHz~2 MHz帶寬,可選的40 dB和60 dB電壓增益。
2、5660C泛美超聲波前置放大器可與超聲探傷儀、測厚儀、聲學發射儀器一起使用,可對超聲信號進行超低噪聲的放大。這款儀器具有以下性能:500 Hz~2 MHz帶寬,可選的40 dB和60 dB電壓增益。
3、5662泛美超聲波前置放大器可與超聲波探傷儀、測厚儀、聲學發射儀器一起使用,可對超聲信號進行超低噪聲的放大。這款儀器具有以下性能:50 kHz~2 MHz帶寬,可選的34 dB和54 dB電壓增益。
4、5670泛美超聲前置放大器可與超聲探傷儀、測厚儀、聲學發射儀器一起使用,可對超聲信號進行超低噪聲的放大。這款儀器具有以下性能:50 kHz~10 MHz帶寬,40 dB電壓增益。
5、5676泛美超聲前置放大器可與超聲探傷儀、測厚儀、聲學發射儀器一起使用,可對超聲信號進行超低噪聲的放大。這款儀器具有以下性能:50 kHz~20 MHz帶寬,40 dB電壓增益。
6、5678泛美超聲前置放大器可與超聲探傷儀、測厚儀、聲學發射儀器一起使用,可對超聲信號進行超低噪聲的放大。這款儀器具有以下性能:200 kHz~40 MHz帶寬,40 dB電壓增益。
7、5682泛美超聲波前置放大器提供超聲信號的低噪聲30 dB放大效果,范圍為500
KHz到25 MHz。前置放大器裝于結實防濺的外殼中,其機身小巧、重量極輕,是一款適用于遠程應用的理想設備。
泛美超聲波前置放大器/奧林巴斯前置放大器panametrics 5660/5662/5670/5676/5678系列英文概述:
Olympus wideband series of Panametrics AC coupled, broadband preamplifiers provides very low noise amplification of ultrasonic signals ranging from 500 Hz to greater than 40 MHz. Specifically designed for use with ultrasonic flaw detection, thickness gaging, and acoustic emission instrumentation, our preamplifiers are a cost-effective solution in general applications requiring high gain/low-noise amplification of low amplitude ultrasonic signals.
Our preamplifiers are ruggedly housed, completely self-contained, simple to operate, battery or AC powered units. They offer performance features such as very low noise (5 µV peak-to-peak noise referred to the input in Model 5660B), input protection for high voltage transients such as transducer excitation pulses, and the ability to drive long coaxial cables (greater than 500 feet or 152 meters with Models 5660B and 5660C). Both fixed gain and switchable gain versions are available, and custom units with special gain or bandwidth are available on special order.
Applications
Certain ultrasonic applications require the addition of a separate preamplifier unit to standard test systems in order to provide the additional gain or broadband signal-to-noise enhancement necessary for optimum signal acquisition. This is often the case in industrial applications involving flaw detection or thickness gaging of thick sections of materials exhibiting high ultrasonic attenuation such as nodular cast iron, brass, bronze, austenitic steel, rubber, Teflon®, or reinforced composites. A preamplifier is also an important component of acoustic emission test systems that require amplification of low signal amplitude events and the ability to drive long cables from remotely located sensors.
Panametrics preamplifiers have also been used in many widely diversified research applications including seismic studies, determination of the size and number versus scattered frequency relationship for acoustic scatterers in water (gas bubbles, zooplankton), crack detection in graphite vacuum arc-melt electrodes, and biological tissue analysis.
泛美超聲波前置放大器/奧林巴斯前置放大器panametrics 5660/5662/5670/5676/5678系列技術規格表:
型號
|
5660B
|
5660C
|
5662
|
5670
|
5676
|
5678
|
電壓增益
|
40&60dB可切換(阻尼>1kΩ)
|
34&54dB可切換(阻尼=50Ω)
|
40dB固定(阻尼=50Ω)
|
帶寬(-3dB)
|
20kHz~2MHz
|
500Hz~2MHz
|
50kHz~5MHz
|
50kHz~10MHz
|
50kHz~20MHz
|
50kHz~40MHz
|
等效輸入噪聲
|
5μVp-p
|
10μVp-p
|
15μVp-p
|
20μVp-p
|
30μVp-p
|
輸入阻抗
|
1MΩ
|
100kΩ
|
輸入電容
|
約320pf
|
約80pf
|
輸入保護
|
300V峰值(脈沖寬度<2μs,大負載循環1%)
|
輸出電壓
|
5Vp-p(阻尼>1kΩ),2Vp-p(阻尼=50Ω)
|
2Vp-p(阻尼=50Ω)
|
輸出阻抗
|
50Ω-與4.7fd串聯
|
大輸出電纜長度
|
>152m
|
15m
|
電源要求
|
電池16V±2V,線電壓110/115或230VAC
|
耗電電流
|
18mA
|
28mA
|
電池壽命
|
100小時
|
70小時
|
尺寸
|
76x51x127mm
|
重量
|
0.64kg
|
工作溫度
|
0~50℃
|
泛美超聲波前置放大器/奧林巴斯前置放大器panametrics 5660/5662/5670/5676/5678系列英文技術規格:
All specifications are subject to change without notice
more information of the panametrics preamplifiers please contact us.